OAR@½ñÈÕºÚÁÏ Community: /library/oar/handle/123456789/470 Fri, 06 Nov 2026 12:56:13 GMT 2026-11-06T12:56:13Z The influence of moving vehicle wakes on the effectiveness of roadside barriers in residential canyons utilising moving reference frames /library/oar/handle/123456789/150617 Title: The influence of moving vehicle wakes on the effectiveness of roadside barriers in residential canyons utilising moving reference frames Authors: Sacco, Jeremy; Micallef, Daniel; Borg, Simon Paul Abstract: Traditional vehicular urban canyon models often overlook the kinetic energy contribution of moving vehicles, which can misrepresent flow conditions at pedestrian level. This research aims to investigate vehicle-induced airflows in residential canyons while maintaining computational complexity to a minimum using CFD simulations with a moving reference frame. Results show that traffic movement is the dominant driver of street-level air currents even at speeds as low as 30 km/h, inducing a lateral flow pattern rather than a standard urban canyon circulating vortex. The performance in attenuating such airflows of 0.5 m and 1 m high roadside barriers is then evaluated and results demonstrate that these barriers effectively shield pedestrian zones by disrupting the lateral flow. Under these symmetric, lateral conditions, roadside barriers exhibit higher reliability compared to their performance in standard urban canyon flows with negligible vehicle effects. These findings suggest that traffic movement must be integrated with aerodynamic assessments to accurately optimize urban microclimate interventions in areas of high traffic throughput. Thu, 01 Jan 2026 00:00:00 GMT /library/oar/handle/123456789/150617 2026-01-01T00:00:00Z Design for deconstruction : closing the material loop in Malta’s construction industry /library/oar/handle/123456789/150423 Title: Design for deconstruction : closing the material loop in Malta’s construction industry Authors: Muscat, Sarah; Dalli Gonzi, Rebecca; Borg, Simon Paul Abstract: The construction industry is frequently criticized for its contribution to global resource depletion, particularly through the disposal of materials from end-of-life buildings. Closing the material loop by transforming waste into a resource is essential for achieving a more sustainable and circular built environment. Design for Deconstruction (DfD), also referred to as Design for Disassembly, is a waste minimization strategy that enables buildings to be dismantled at the end of their service life, allowing components and materials to be reused or recycled rather than landfilled. This study investigates the potential for implementing DfD within the Maltese construction industry, where construction and demolition waste remains a significant environmental concern. A quantitative research approach was adopted through the distribution of a survey among key industry stakeholders to assess current practices, levels of awareness, perceived barriers, and potential drivers for adoption. The findings indicate that time and cost constraints, limited education and training, entrenched industry culture, and existing policies and regulations represent major obstacles to DfD implementation. However, financial incentives, strengthened regulatory frameworks, and enhanced professional training emerged as key enablers that could facilitate wider adoption. Although carried out within the Maltese context, the results reflect broader challenges faced by small islands and resource-constrained regions, highlighting DfD’s wider applicability as a systemic strategy for promoting circular construction and reducing waste in the built environment. Thu, 01 Oct 2026 00:00:00 GMT /library/oar/handle/123456789/150423 2026-10-01T00:00:00Z The potential of switchable glazing in cooling dominated climates /library/oar/handle/123456789/150374 Title: The potential of switchable glazing in cooling dominated climates Authors: Magri, Etienne; Buhagiar, Vincent; Overend, Mauro Abstract: The design trend of most commercial and office buildings over the past three decades focused on attaining a façade design with the highest possible window to wall ratio. Whereas this approach appears to satisfy the aesthetic scope of developing buildings that look ‘modern and transparent’ to maximise on real estate value, the demand for heating and cooling of these buildings tends to fall short of what one should expect. Literature review shows the possible benefits of switchable glass. This paper proposes a methodology for a novel switchable glazing assembly identified as having the potential of offering increased occupant comfort, particularly in providing sufficient daylight and glare control without diminishing the view quality. The hypothesis is that switchable glazing may have a substantial potential to achieve lower cooling loads and improved indoor visual comfort without compromising views and a positive outlook. Sun, 01 Jan 2023 00:00:00 GMT /library/oar/handle/123456789/150374 2023-01-01T00:00:00Z Optimizing space heating and cooling through digital control and predictive mean vote thermal comfort index /library/oar/handle/123456789/149019 Title: Optimizing space heating and cooling through digital control and predictive mean vote thermal comfort index Authors: Xuereb, Matthew; Borg, Simon Paul; Licari, John Abstract: Increased awareness on sustainability and rising energy costs have intensified the need for more efficient and occupant-responsive building operation. In this context, this study evaluates the use of Fanger’s Predicted Mean Vote (PMV) index as a Heating, Ventilation and Air Conditioning (HVAC) control strategy within Building Management Systems (BMS), comparing it to traditional occupant-driven or fixed-range temperature set-point methods commonly used in commercial and public buildings. Three consecutive occupied-environment tests were conducted, each employing a different control approach: full occupant control, restricted temperature-range control, and a PMV-based fixed set-point. HVAC energy consumption and indoor environmental conditions were collected through the building installed BMS and then analysed together with occupant thermal comfort surveys. Results indicate that PMV-based control is a feasible and potentially effective methodology, capable of maintaining thermal comfort while reducing energy consumption. The study further shows that more refinement and broader testing could enable PMV-driven control to support more efficient, comfort-oriented building operation. Sat, 01 Aug 2026 00:00:00 GMT /library/oar/handle/123456789/149019 2026-08-01T00:00:00Z