OAR@˝ńČŐşÚÁĎ Collection: /library/oar/handle/123456789/428 Sat, 07 Nov 2026 16:07:45 GMT 2026-11-07T16:07:45Z Intaglio surface accuracy of temporary crowns fabricated by additive versus subtractive CAD/CAM methods /library/oar/handle/123456789/149760 Title: Intaglio surface accuracy of temporary crowns fabricated by additive versus subtractive CAD/CAM methods Authors: Ayres, Ana Paula; Rodrigues, Nicole; Pinhata-Baptista, Otavio Henrique; Pradies, Guillermo; Cortes, Arthur R. G. Abstract: The success of temporary restorations depends on their marginal and internal adaptation, which are influenced by the manufacturing method. This study evaluated the intaglio surface accuracy, internal fit, and marginal fit of provisional crowns fabricated via subtractive (milling) and additive (3D printing) CAD/CAM technologies. Three milling systems—CEREC Primemill (4-axis), PrograMill Dry (5-axis), and Zirkonzahn M1 (5-axis)—and three 3D printers—Phrozen Mini 4K (LCD), SprintRay Pro95S (DLP), and Stratasys Objet30 (PolyJet)—were evaluated. For 3D printing, five build orientations (0°, 30°, 45°, 60°, and 90°) were tested. A total of 360 crowns were fabricated. Accuracy was quantified by Root Mean Square (RMS) deviation, and fit was assessed using the triple-scan method. Results indicated that build angles of 0° and 30° yielded the best performance for printed crowns (p < 0.05). While milling systems showed significantly superior intaglio accuracy and marginal fit compared to 3D printing (p < 0.05), no significant differences were found in internal fit between the two methods (p > 0.05). Milling offers higher dimensional predictability, but both approaches are clinically viable when optimized parameters are utilized. Thu, 01 Jan 2026 00:00:00 GMT /library/oar/handle/123456789/149760 2026-01-01T00:00:00Z Diagnostic performance of an intraoral scanner for caries detection on permanent tooth surfaces /library/oar/handle/123456789/149758 Title: Diagnostic performance of an intraoral scanner for caries detection on permanent tooth surfaces Authors: Agius, Anne-Marie; No-Cortes, Juliana; Cortes, Arthur R. G.; Attard, Nikolai J.; Gatt, Gabriella Abstract: Intraoral scanners with fluorescence technology (IOSFT) include a caries detection feature in addition to their standard scanning function. The aim of this study was to determine the diagnostic performance of the caries detection tool of the IOSFT Trios 4® on permanent premolar and molar surfaces when compared to visual and radiographic International Caries Detection and Assessment System (ICDAS). Methods: Participants (n = 71, age 6–88 years) were examined under standardised conditions using ICDAS criteria for visual caries detection of occlusal and smooth surfaces. Bitewing (BW) radiographs were used to examine proximal surfaces using ICDAS radiographic criteria. Finally, participants underwent an intraoral scan of both the maxilla and the mandible according to the manufacturer’s instructions. The automated caries detection (ACD) output on the IOSFT software was compared to the visual ICDAS scores obtained clinically for occlusal and free smooth (buccal and lingual) surfaces; the IOSFT caries de detection output was compared to radiographic ICDAS scores from BW radiographs for interproximal (mesial and distal) surfaces. Sensitivity, specificity, and accuracy values for each tooth surface were calculated. Results: Out of 3,684 permanent tooth surfaces examined, 461 surfaces with dental caries were included in the analysis. 392 were initial lesions (ICDAS 1–2), while 69 were moderate/severe (ICDAS 3–6). There was a moderate positive correlation (r = 0.4, p < 0.001) when comparing all ICDAS scores to IOSFT ACD categories for unrestored permanent occlusal surfaces. IOSFT ACD accuracy was higher for moderate/advanced lesions (ICDAS 3–6) lesions when compared to initial (ICDAS 1–2) ones (81% vs. 37.7%). For unrestored smooth surfaces, weak positive correlations were found when comparing all ICDAS scores to IOSFT ACD categories (r = 0.19, p < 0.001). Accuracy results for smooth surfaces were 93.5% for moderate/advanced and 77.1% for initial lesions. Correlations between BW ICDAS scores and IOSFT ACD scores for proximal surfaces were weak (r = 0.07, p = 0.019). Diagnostic accuracy was higher for moderate/ advanced lesions when compared to initial ones (83.5% vs. 40.4%). There was a weak correlation between IOSFT ACD categories and ICDAS/visual categories for restored occlusal surfaces (r = 0.029, p = 0.68). Conclusion: IOSFT cannot currently replace visual and radiographic exams for caries detection. Wed, 01 Jan 2025 00:00:00 GMT /library/oar/handle/123456789/149758 2025-01-01T00:00:00Z Patient acceptance, time efficiency, and inter-operator agreement in intra-oral scanning with fluorescence technology for caries detection /library/oar/handle/123456789/149756 Title: Patient acceptance, time efficiency, and inter-operator agreement in intra-oral scanning with fluorescence technology for caries detection Authors: Agius, Anne-Marie; No-Cortes, Juliana; Cortes, Arthur R. G.; Attard, Nikolai J.; Gatt, Gabriella Abstract: Background: Intra-oral scanners (IOS) have been widely used to obtain digital impressions for treatment planning and to enable a full digital workflow on virtual patients. Much less is known about the use of IOS for caries detection. This study focuses on the use of the scanners for caries detection and investigates the number of images, time and patient experiences as well as differences between operators.; Methods: Participants were recruited if they had caries present, their teeth were cleaned using a prophy brush and water and then scanned in a standardised manner. Some participants were scanned a second time by another operator. The automated caries detection results as well as the number of images needed and time taken per jaw scanned was noted. Participants were also asked to complete a questionnaire regarding their experience during the scanning process.; Results: Data sets (scanning time and number of images) from 78 participants were both found to be non-normal using the Shapiro Wilk test (p < 0.001). A Mann-Whitney U test revealed that both the time taken (U = 17772.500, z = -8.066, p < 0.001) as well as the number of images needed (U = 15252.000, z =-9.651, p < 0.0001) were significantly higher for the maxilla when compared to the mandible. The same test also showed that significantly more time (U = 102718.500, z = 14.505, p < 0.0001) and images (U = 108395.500, z = 16.457, p < 0.0001) were needed for scanning permanent teeth when compared to primary teeth. The questionnaire revealed that the vast majority of participants (87%) found the scanning procedure comfortable and acceptable but there were statistically significant differences in discomfort experienced in different areas of the mouth, with the most uncomfortable area scanned being the distal surfaces of the upper molars (p < 0.001). A Wilcoxon Signed Rank test revealed no significance difference in jaw scanning time (z = 0.118, n = 12, p = 0.906) and number of images taken per arch (z = 1.255, n = 12, p = 0.209) between the operators. Cohen’s Weighted Kappa yielded the following significant result: Îş = 0.744, p < 0.0001 showing good agreement between the operators’ automated caries detection results. Wed, 01 Jan 2025 00:00:00 GMT /library/oar/handle/123456789/149756 2025-01-01T00:00:00Z Digital workflow for a customized 3D-printed palatal stent to protect the donor site for connective tissue grafting /library/oar/handle/123456789/147357 Title: Digital workflow for a customized 3D-printed palatal stent to protect the donor site for connective tissue grafting Authors: Teixeira-Neto, Alexandre Domingues; Ayres, Ana Paula; Akhmad, Rafik; de Moura e Costa, Alan Jony; Burgoa, Shaban; No-Cortes, Juliana; Gutierrez, Virgilio; Beuer, Florian; Cortes, Arthur R. G. Abstract: Connective tissue grafting remains the gold standard method for soft tissue augmentation in periodontal therapy. However, donor site morbidity is a challenge, as patient discomfort is frequently reported due to prolonged healing time with pain, inflammation, bleeding, and sometimes even infection. Current techniques aim to avoid complications by relying on collagen membranes, platelet-rich fibrin (PRF), and palatal stents. This report introduces a digital workflow to fabricate 3D-printed palatal stents individualized on virtual patients using an implant planning software program. The 3D-printed palatal stent is suggested to be more comfortable and effective to achieve better patient-reported outcomes related to connective tissue grafting; Bindegewebetransplantate (BGT) sind nach wie vor der Goldstandard fĂĽr die Weichgewebeaugmentation in der Parodontalchirurgie. Problematisch bleibt jedoch die Morbidität der Entnahmestelle, denn die Patienten berichten häufig von Beschwerden aufgrund des langwierigen Heilungsprozesses mit Schmerzen, EntzĂĽndung, Blutung und in manchen Fällen sogar einer Infektion. Neuere Techniken versuchen solche Komplikationen mithilfe von Kollagenmembranen, thrombozytenreichem Fibrin (PRF) und Verbandplatten zu verhindern. Dieser Fallbericht zeigt einen digitalen Workflow fĂĽr die Herstellung 3D-gedruckter Verbandplatten fĂĽr den Gaumen, die nach Erstellung eines digitalen Patienten in einer Implantatplanungssoftware individuell konstruiert werden. Die 3D-gedruckte palatinale Verbandplatte verbessert den Komfort und die Patient-Reported Outcomes im Zusammenhang mit Bindegewebetransplantationen. Thu, 01 Jan 2026 00:00:00 GMT /library/oar/handle/123456789/147357 2026-01-01T00:00:00Z